Preheating accoring EN 1011-2 and SEW 088 based on cet Fill out the form and see your minimum preheat temperatur immediately Preheat form PREHEAT CALCULATION ACCORDING TO EN-1011-2 AND SEW 088 (BASED ON CET) Project Base Metal Remarks MATERIAL ANALYSES C Mn Mo Cr Cu Ni V Si CE CET HEAT INPUT CALCULATION Q ( kJ/mm ) A V v (mm/min) Process k-factor k-factors SAW=1,SMAW=0,8,GMAW=0,8FCAW=0,8, GTAW=0,6 PAW =0,6 Q SMAW / 111 SAW / 121 GMAW / 135 FCAW / 136 GTAW /141 PAW / 151 0.8 HYDROGEN AND MATERIAL THICKNESS Hydrogen content consumable HD Material thickness d Calculation of Formulas Abbr Result Thickness influence Tpd=160 x tanh(d/35)-110 Tpd Hydrogen influence TpHD=62 x HD035-100 TpHD Heat input influence TpQ= (53 x CET-32) x Q-53 x CET+32 TpQ CET Influence TpCET=750 x CET-150 TpCET MINIMUM PREHEAT TEMPERATURE Tp IN °C Expected relative 3D cool down time (T8/5) for buttwelds (assumed F3 factor = 1) t 8/5 in s n/a DATE SIGN